The BioHermes BH60 Automated Glycohemoglobin Analyzer is a high-throughput, benchtop laboratory system engineered for the precise quantification of Glycated Hemoglobin (HbA1c) and Fetal Hemoglobin (HbF). Operating on the clinical "gold standard" of Ion-Exchange High-Performance Liquid Chromatography (HPLC), this instrument provides reliable variant detection and accurate HbA1c monitoring for medium-to-large hospitals and diagnostic centers.
| Category | Parameter / Component | Specification Details |
| Analytical Baseline | Methodology | Ion-Exchange High-Performance Liquid Chromatography (HPLC) |
| Optical System | Double-wavelength optical photometer measuring at 415nm | |
| Testing Parameters | Stable Glycated Hemoglobin (HbA1c), Fetal Hemoglobin (HbF) | |
| Testing Range | 3.0% to 20.0% HbA1c | |
| Precision Performance | Repeatability Coefficient of Variation (CV) ≤ 1.0% | |
| Standardization | NGSP certified & traceably aligned to IFCC global standards | |
| Throughput & Speed | Standard Mode | 60 seconds / test |
| Sample Processing | On-Board Loading | Continuous batch loading track up to 110 samples |
| Sample Ingestion | Whole blood (primary vacuum tubes) or pre-diluted blood | |
| Aspiration Volume | Whole Blood: ≤ 5 µL (Requires ≥ 1.0 mL total tube volume) Pre-diluted: Uses sample cups holding ≥ 0.5 mL total volume | |
| Homogenization | Integrated automatic stirring mechanism prior to aspiration | |
| Emergency Handling | Dedicated STAT priority pathway for immediate insertion | |
| Reagents & Consumables | Analytical Column Life | Rated lifecycle of 3,000 complete test cycles |
| Reagent Composition | Elution Buffer A, Elution Buffer B, Hemolysis/Wash Buffer H | |
| Hardware Security | Integrated NFC/RFID contactless reader for reagent card syncing | |
| Tracking Subsystem | Smart on-board reagent consumption, expiry, and pressure tracking | |
| Computing & Interfaces | User Interface | High-resolution touchscreen display with standalone tactile operational keypads |
| ID Management | Internal automated rotating barcode reader | |
| Memory Capacity | 20,000 patient records (including full color chromatograms) 2,000 Quality Control (QC) curves 100 calibration log matrices | |
| Connectivity | Bidirectional communication via native ports to LIS and HIS | |
| Hardware & Physics | Dimensions | 550 mm (Width) × 540 mm (Depth) × 570 mm (Height) |
| Weight | 45 kg (99 lbs) empty | |
| Electrical Supply | Universal self-sensing AC 110V–220V (±10%), 50Hz–60Hz (±3%) | |
| Power Consumption | Maximum active power configuration of 200 VA | |
| Operating Atmosphere | Temperature: 10°C to 35°C Humidity: 10% to 85% RH (non-condensing) |